10,000 psi | |
Internal sample | |
360 µm | 100 µm |
Model C74MH internal sample injectors with 100µm bore are available with 4, 10, or 20 nanoliter sample size. Valves can be actuated manually or automated with pneumatic or electric actuators.
A complete valve product number (in the table below) includes information about the sample size, actuator, and mounting hardware.
Valves include the appropriate 360 µm fittings.
Select the desired sample size below to view product numbers:
For use with | SELECT sample size |
---|---|
Metal tubing | |
FS tubing | |
PEEK tubing |
Internal sample injectors for use with metal tubing
4 nanoliter sample size
Port size | Description | Product No. | |
---|---|---|---|
100 µm (.004") |
Manual | C74MH-4674-.004 | |
With air actuator | C74MH-4674-.004A | ||
With Modular Universal Actuator Choose interface: |
Digital I/O | C74MH-4674-.004UMH | |
RS-232 | C74MH-4674-.004UMHA | ||
RS-485 | C74MH-4674-.004UMHF | ||
BCD | C74MH-4674-.004UMHC | ||
With universal actuator Choose interface: |
Digital I/O | C74MH-4674-.004EUH | |
RS-232 | C74MH-4674-.004EUHA | ||
RS-485 | C74MH-4674-.004EUHF | ||
USB | C74MH-4674-.004EUHB | ||
BCD | C74MH-4674-.004EUHC | ||
Replacement valve | C74MH-4674-.004D | ||
Replacement rotor | C74N-46R-.004 | ||
Replacement stator | C74N-4C7 |
Internal sample injectors for use with metal tubing
10 nanoliter sample size
Port size | Description | Product No. | |
---|---|---|---|
100 µm (.004") |
Manual | C74MH-4674-.01 | |
With air actuator | C74MH-4674-.01A | ||
With Modular Universal Actuator Choose interface: |
Digital I/O | C74MH-4674-.01UMH | |
RS-232 | C74MH-4674-.01UMHA | ||
RS-485 | C74MH-4674-.01UMHF | ||
BCD | C74MH-4674-.01UMHC | ||
With universal actuator Choose interface: |
Digital I/O | C74MH-4674-.01EUH | |
RS-232 | C74MH-4674-.01EUHA | ||
RS-485 | C74MH-4674-.01EUHF | ||
USB | C74MH-4674-.01EUHB | ||
BCD | C74MH-4674-.01EUHC | ||
Replacement valve | C74MH-4674-.01D | ||
Replacement rotor | C74N-46R-.01 | ||
Replacement stator | C74N-4C7 |
Internal sample injectors for use with metal tubing
20 nanoliter sample size
Port size | Description | Product No. | |
---|---|---|---|
100 µm (.004") |
Manual | C74MH-4674-.02 | |
With air actuator | C74MH-4674-.02A | ||
With Modular Universal Actuator Choose interface: |
Digital I/O | C74MH-4674-.02UMH | |
RS-232 | C74MH-4674-.02UMHA | ||
RS-485 | C74MH-4674-.02UMHF | ||
BCD | C74MH-4674-.02UMHC | ||
With universal actuator Choose interface: |
Digital I/O | C74MH-4674-.02EUH | |
RS-232 | C74MH-4674-.02EUHA | ||
RS-485 | C74MH-4674-.02EUHF | ||
USB | C74MH-4674-.02EUHB | ||
BCD | C74MH-4674-.02EUHC | ||
Replacement valve | C74MH-4674-.02D | ||
Replacement rotor | C74N-46R-.02 | ||
Replacement stator | C74N-4C7 |
Internal sample injectors for use with fused silica tubing
4 nanoliter sample size
Port size | Description | Product No. | |
---|---|---|---|
100 µm (.004") |
Manual | C74MFSH-4674-.004 | |
With air actuator | C74MFSH-4674-.004A | ||
With Modular Universal Actuator Choose interface: |
Digital I/O | C74MFSH-4674-.004UMH | |
RS-232 | C74MFSH-4674-.004UMHA | ||
RS-485 | C74MFSH-4674-.004UMHF | ||
BCD | C74MFSH-4674-.004UMHC | ||
With universal actuator Choose interface: |
Digital I/O | C74MFSH-4674-.004EUH | |
RS-232 | C74MFSH-4674-.004EUHA | ||
RS-485 | C74MFSH-4674-.004EUHF | ||
USB | C74MFSH-4674-.004EUHB | ||
BCD | C74MFSH-4674-.004EUHC | ||
Replacement valve | C74MFSH-4674-.004D | ||
Replacement rotor | C74N-46R-.004 | ||
Replacement stator | C74N-4C7 |
Internal sample injectors for use with fused silica tubing
10 nanoliter sample size
Port size | Description | Product No. | |
---|---|---|---|
100 µm (.004") |
Manual | C74MFSH-4674-.01 | |
With air actuator | C74MFSH-4674-.01A | ||
With Modular Universal Actuator Choose interface: |
Digital I/O | C74MFSH-4674-.01UMH | |
RS-232 | C74MFSH-4674-.01UMHA | ||
RS-485 | C74MFSH-4674-.01UMHF | ||
BCD | C74MFSH-4674-.01UMHC | ||
With universal actuator Choose interface: |
Digital I/O | C74MFSH-4674-.01EUH | |
RS-232 | C74MFSH-4674-.01EUHA | ||
RS-485 | C74MFSH-4674-.01EUHF | ||
USB | C74MFSH-4674-.01EUHB | ||
BCD | C74MFSH-4674-.01EUHC | ||
Replacement valve | C74MFSH-4674-.01D | ||
Replacement rotor | C74N-46R-.01 | ||
Replacement stator | C74N-4C7 |
Internal sample injectors for use with fused silica tubing
20 nanoliter sample size
Port size | Description | Product No. | |
---|---|---|---|
100 µm (.004") |
Manual | C74MFSH-4674-.02 | |
With air actuator | C74MFSH-4674-.02A | ||
With Modular Universal Actuator Choose interface: |
Digital I/O | C74MFSH-4674-.02UMH | |
RS-232 | C74MFSH-4674-.02UMHA | ||
RS-485 | C74MFSH-4674-.02UMHF | ||
BCD | C74MFSH-4674-.02UMHC | ||
With universal actuator Choose interface: |
Digital I/O | C74MFSH-4674-.02EUH | |
RS-232 | C74MFSH-4674-.02EUHA | ||
RS-485 | C74MFSH-4674-.02EUHF | ||
USB | C74MFSH-4674-.02EUHB | ||
BCD | C74MFSH-4674-.02EUHC | ||
Replacement valve | C74MFSH-4674-.02D | ||
Replacement rotor | C74N-46R-.02 | ||
Replacement stator | C74N-4C7 |
Internal sample injectors for use with PEEK tubing
4 nanoliter sample size
Port size | Description | Product No. | |
---|---|---|---|
100 µm (.004") |
Manual | C74MPKH-4674-.004 | |
With air actuator | C74MPKH-4674-.004A | ||
With Modular Universal Actuator Choose interface: |
Digital I/O | C74MPKH-4674-.004UMH | |
RS-232 | C74MPKH-4674-.004UMHA | ||
RS-485 | C74MPKH-4674-.004UMHF | ||
BCD | C74MPKH-4674-.004UMHC | ||
With universal actuator Choose interface: |
Digital I/O | C74MPKH-4674-.004EUH | |
RS-232 | C74MPKH-4674-.004EUHA | ||
RS-485 | C74MPKH-4674-.004EUHF | ||
USB | C74MPKH-4674-.004EUHB | ||
BCD | C74MPKH-4674-.004EUHC | ||
Replacement valve | C74MPKH-4674-.004D | ||
Replacement rotor | C74N-46R-.004 | ||
Replacement stator | C74N-4C7 |
Internal sample injectors for use with PEEK tubing
10 nanoliter sample size
Port size | Description | Product No. | |
---|---|---|---|
100 µm (.004") |
Manual | C74MPKH-4674-.01 | |
With air actuator | C74MPKH-4674-.01A | ||
With Modular Universal Actuator Choose interface: |
Digital I/O | C74MPKH-4674-.01UMH | |
RS-232 | C74MPKH-4674-.01UMHA | ||
RS-485 | C74MPKH-4674-.01UMHF | ||
BCD | C74MPKH-4674-.01UMHC | ||
With universal actuator Choose interface: |
Digital I/O | C74MPKH-4674-.01EUH | |
RS-232 | C74MPKH-4674-.01EUHA | ||
RS-485 | C74MPKH-4674-.01EUHF | ||
USB | C74MPKH-4674-.01EUHB | ||
BCD | C74MPKH-4674-.01EUHC | ||
Replacement valve | C74MPKH-4674-.01D | ||
Replacement rotor | C74N-46R-.01 | ||
Replacement stator | C74N-4C7 |
Internal sample injectors for use with PEEK tubing
20 nanoliter sample size
Port size | Description | Product No. | |
---|---|---|---|
100 µm (.004") |
Manual | C74MPKH-4674-.02 | |
With air actuator | C74MPKH-4674-.02A | ||
With Modular Universal Actuator Choose interface: |
Digital I/O | C74MPKH-4674-.02UMH | |
RS-232 | C74MPKH-4674-.02UMHA | ||
RS-485 | C74MPKH-4674-.02UMHF | ||
BCD | C74MPKH-4674-.02UMHC | ||
With universal actuator Choose interface: |
Digital I/O | C74MPKH-4674-.02EUH | |
RS-232 | C74MPKH-4674-.02EUHA | ||
RS-485 | C74MPKH-4674-.02EUHF | ||
USB | C74MPKH-4674-.02EUHB | ||
BCD | C74MPKH-4674-.02EUHC | ||
Replacement valve | C74MPKH-4674-.02D | ||
Replacement rotor | C74N-46R-.02 | ||