GC Internal Sample Injectors - 1/16", 0.40 mm ports

Med temp
Internal sample
1/16" 0.40 mm
Valco GC valve
GC internal sample injector - 1/16" fittings, .40 mm ports
close move

A complete valve product number includes information about the valve, actuator, and mounting hardware. Valves include stainless steel nuts and ferrules.

Select the desired sample size below to view product numbers:

.06 microliter

.1 microliter

.2 microliter

.5 microliter

Med temp
Internal sample
1/16" 0.40 mm
4 port schematic

.06 µl injectors

Microelectric and universal actuators:
   24 VDC, with 110/230 VAC to 24 VDC power supply

Actuation Standoff Product No.
Manual none CI4WE.06
2" 2CI4WE.06
3" 3CI4WE.06
4" 4CI4WE.06
6" 6CI4WE.06
With air actuator none ACI4WE.06
2" A2CI4WE.06
3" A3CI4WE.06
4" A4CI4WE.06
6" A6CI4WE.06
With Modular Universal Actuator
Choose interface:
Digital I/O none UMH-CI4WE.06
2" UMH-2CI4WE.06
3" UMH-3CI4WE.06
4" UMH-4CI4WE.06
6" UMH-6CI4WE.06
RS-232 none UMHA-CI4WE.06
2" UMHA-2CI4WE.06
3" UMHA-3CI4WE.06
4" UMHA-4CI4WE.06
6" UMHA-6CI4WE.06
RS-485 none UMHF-CI4WE.06
2" UMHF-2CI4WE.06
3" UMHF-3CI4WE.06
4" UMHF-4CI4WE.06
6" UMHF-6CI4WE.06
BCD none UMHC-CI4WE.06
2" UMHC-2CI4WE.06
3" UMHC-3CI4WE.06
4" UMHC-4CI4WE.06
6" UMHC-6CI4WE.06
Universal actuator
Choose interface:
Digital I/O none EUH-CI4WE.06
2" EUH-2CI4WE.06
3" EUH-3CI4WE.06
4" EUH-4CI4WE.06
6" EUH-6CI4WE.06
RS-232 none EUHA-CI4WE.06
2" EUHA-2CI4WE.06
3" EUHA-3CI4WE.06
4" EUHA-4CI4WE.06
6" EUHA-6CI4WE.06
RS-485 none EUHF-CI4WE.06
2" EUHF-2CI4WE.06
3" EUHF-3CI4WE.06
4" EUHF-4CI4WE.06
6" EUHF-6CI4WE.06
USB none EUHB-CI4WE.06
2" EUHB-2CI4WE.06
3" EUHB-3CI4WE.06
4" EUHB-4CI4WE.06
6" EUHB-6CI4WE.06
BCD none EUHC-CI4WE.06
2" EUHC-2CI4WE.06
3" EUHC-3CI4WE.06
4" EUHC-4CI4WE.06
6" EUHC-6CI4WE.06
Replacement parts Product No.
Valve (for use with existing actuator) DCI4WE.06
Rotor SSACI4WE.06
Med temp
Internal sample
1/16" 0.40 mm
4 port schematic

.1 µl injectors

Microelectric and universal actuators:
   24 VDC, with 110/230 VAC to 24 VDC power supply

Actuation Standoff Product No.
Manual none CI4WE.1
2" 2CI4WE.1
3" 3CI4WE.1
4" 4CI4WE.1
6" 6CI4WE.1
With air actuator none ACI4WE.1
2" A2CI4WE.1
3" A3CI4WE.1
4" A4CI4WE.1
6" A6CI4WE.1
With Modular Universal Actuator
Choose interface:
Digital I/O none UMH-CI4WE.1
2" UMH-2CI4WE.1
3" UMH-3CI4WE.1
4" UMH-4CI4WE.1
6" UMH-6CI4WE.1
RS-232 none UMHA-CI4WE.1
2" UMHA-2CI4WE.1
3" UMHA-3CI4WE.1
4" UMHA-4CI4WE.1
6" UMHA-6CI4WE.1
RS-485 none UMHF-CI4WE.1
2" UMHF-2CI4WE.1
3" UMHF-3CI4WE.1
4" UMHF-4CI4WE.1
6" UMHF-6CI4WE.1
BCD none UMHC-CI4WE.1
2" UMHC-2CI4WE.1
3" UMHC-3CI4WE.1
4" UMHC-4CI4WE.1
6" UMHC-6CI4WE.1
Universal actuator
Choose interface:
Digital I/O none EUH-CI4WE.1
2" EUH-2CI4WE.1
3" EUH-3CI4WE.1
4" EUH-4CI4WE.1
6" EUH-6CI4WE.1
RS-232 none EUHA-CI4WE.1
2" EUHA-2CI4WE.1
3" EUHA-3CI4WE.1
4" EUHA-4CI4WE.1
6" EUHA-6CI4WE.1
RS-485 none EUHF-CI4WE.1
2" EUHF-2CI4WE.1
3" EUHF-3CI4WE.1
4" EUHF-4CI4WE.1
6" EUHF-6CI4WE.1
USB none EUHB-CI4WE.1
2" EUHB-2CI4WE.1
3" EUHB-3CI4WE.1
4" EUHB-4CI4WE.1
6" EUHB-6CI4WE.1
BCD none EUHC-CI4WE.1
2" EUHC-2CI4WE.1
3" EUHC-3CI4WE.1
4" EUHC-4CI4WE.1
6" EUHC-6CI4WE.1
Replacement parts Product No.
Valve (for use with existing actuator) DCI4WE.1
Rotor SSACI4WE.1
Med temp
Internal sample
1/16" 0.40 mm
4 port schematic

.2 µl injectors

Microelectric and universal actuators:
   24 VDC, with 110/230 VAC to 24 VDC power supply

Actuation Standoff Product No.
Manual none CI4WE.2
2" 2CI4WE.2
3" 3CI4WE.2
4" 4CI4WE.2
6" 6CI4WE.2
With air actuator none ACI4WE.2
2" A2CI4WE.2
3" A3CI4WE.2
4" A4CI4WE.2
6" A6CI4WE.2
With Modular Universal Actuator
Choose interface:
Digital I/O none UMH-CI4WE.2
2" UMH-2CI4WE.2
3" UMH-3CI4WE.2
4" UMH-4CI4WE.2
6" UMH-6CI4WE.2
RS-232 none UMHA-CI4WE.2
2" UMHA-2CI4WE.2
3" UMHA-3CI4WE.2
4" UMHA-4CI4WE.2
6" UMHA-6CI4WE.2
RS-485 none UMHF-CI4WE.2
2" UMHF-2CI4WE.2
3" UMHF-3CI4WE.2
4" UMHF-4CI4WE.2
6" UMHF-6CI4WE.2
BCD none UMHC-CI4WE.2
2" UMHC-2CI4WE.2
3" UMHC-3CI4WE.2
4" UMHC-4CI4WE.2
6" UMHC-6CI4WE.2
Universal actuator
Choose interface:
Digital I/O none EUH-CI4WE.2
2" EUH-2CI4WE.2
3" EUH-3CI4WE.2
4" EUH-4CI4WE.2
6" EUH-6CI4WE.2
RS-232 none EUHA-CI4WE.2
2" EUHA-2CI4WE.2
3" EUHA-3CI4WE.2
4" EUHA-4CI4WE.2
6" EUHA-6CI4WE.2
RS-485 none EUHF-CI4WE.2
2" EUHF-2CI4WE.2
3" EUHF-3CI4WE.2
4" EUHF-4CI4WE.2
6" EUHF-6CI4WE.2
USB none EUHB-CI4WE.2
2" EUHB-2CI4WE.2
3" EUHB-3CI4WE.2
4" EUHB-4CI4WE.2
6" EUHB-6CI4WE.2
BCD none EUHC-CI4WE.2
2" EUHC-2CI4WE.2
3" EUHC-3CI4WE.2
4" EUHC-4CI4WE.2
6" EUHC-6CI4WE.2
Replacement parts Product No.
Valve (for use with existing actuator) DCI4WE.2
Rotor SSACI4WE.2
Med temp
Internal sample
1/16" 0.40 mm
4 port schematic

.5 µl injectors

Microelectric and universal actuators:
   24 VDC, with 110/230 VAC to 24 VDC power supply

Actuation Standoff Product No.
Manual none CI4WE.5
2" 2CI4WE.5
3" 3CI4WE.5
4" 4CI4WE.5
6" 6CI4WE.5
With air actuator none ACI4WE.5
2" A2CI4WE.5
3" A3CI4WE.5
4" A4CI4WE.5
6" A6CI4WE.5
With Modular Universal Actuator
Choose interface:
Digital I/O none UMH-CI4WE.5
2" UMH-2CI4WE.5
3" UMH-3CI4WE.5
4" UMH-4CI4WE.5
6" UMH-6CI4WE.5
RS-232 none UMHA-CI4WE.5
2" UMHA-2CI4WE.5
3" UMHA-3CI4WE.5
4" UMHA-4CI4WE.5
6" UMHA-6CI4WE.5
RS-485 none UMHF-CI4WE.5
2" UMHB-2CI4WE.5
3" UMHB-3CI4WE.5
4" UMHB-4CI4WE.5
6" UMHB-6CI4WE.5
BCD none UMHC-CI4WE.5
2" UMHC-2CI4WE.5
3" UMHC-3CI4WE.5
4" UMHC-4CI4WE.5
6" UMHC-6CI4WE.5
Universal actuator
Choose interface:
Digital I/O none EUH-CI4WE.5
2" EUH-2CI4WE.5
3" EUH-3CI4WE.5
4" EUH-4CI4WE.5
6" EUH-6CI4WE.5
RS-232 none EUHA-CI4WE.5
2" EUHA-2CI4WE.5
3" EUHA-3CI4WE.5
4" EUHA-4CI4WE.5
6" EUHA-6CI4WE.5
RS-485 none EUHF-CI4WE.5
2" EUHF-2CI4WE.5
3" EUHF-3CI4WE.5
4" EUHF-4CI4WE.5
6" EUHF-6CI4WE.5
USB none EUHB-CI4WE.5
2" EUHB-2CI4WE.5
3" EUHB-3CI4WE.5
4" EUHB-4CI4WE.5
6" EUHB-6CI4WE.5
BCD none EUHC-CI4WE.5
2" EUHC-2CI4WE.5
3" EUHC-3CI4WE.5
4" EUHC-4CI4WE.5
6" EUHC-6CI4WE.5
Replacement parts Product No.
Valve (for use with existing actuator) DCI4WE.5
Rotor SSACI4WE.5

SPECIFICATIONS

Max pressure: 1000 psi
Max temp: 175°C
Body: Nitronic 60
Rotor: Valcon E

OPTIONS

Contact us for more info about:

  • Non-standard valve body materials

MORE INFORMATION

STANDOFFS

GC valves usually require a standoff - an extension between the valve and actuator which allows the valve to be mounted in the heated zone while the actuator or handle remains outside at ambient temperature.