GC Internal Sample Injectors - 1/16", 0.75 mm ports

Med temp
Internal sample
1/16" 0.75 mm

A complete valve product number includes information about the valve, actuator, and mounting hardware. Valves include stainless steel nuts and ferrules.

Select the desired sample size below to view product numbers:

.2 microliter

.5 microliter

1 microliter

2 microliter

Med temp
Internal sample
1/16" 0.75 mm
4 port schematic

.2 µl injectors

Microelectric and universal actuators:
   24 VDC, with 110/230 VAC to 24 VDC power supply

Actuation Standoff Product No.
Manual none CI4UWE.2
2" 2CI4UWE.2
3" 3CI4UWE.2
4" 4CI4UWE.2
6" 6CI4UWE.2
With air actuator none ACI4UWE.2
2" A2CI4UWE.2
3" A3CI4UWE.2
4" A4CI4UWE.2
6" A6CI4UWE.2
With Modular Universal Actuator
Choose interface:
Standard none UMD-CI4UWE.2
2" UMD-2CI4UWE.2
3" UMD-3CI4UWE.2
4" UMD-4CI4UWE.2
6" UMD-6CI4UWE.2
RS-232 none UMDA-CI4UWE.2
2" UMDA-2CI4UWE.2
3" UMDA-3CI4UWE.2
4" UMDA-4CI4UWE.2
6" UMDA-6CI4UWE.2
RS-485 none UMDF-CI4UWE.2
2" UMDF-2CI4UWE.2
3" UMDF-3CI4UWE.2
4" UMDF-4CI4UWE.2
6" UMDF-6CI4UWE.2
BCD none UMDC-CI4UWE.2
2" UMDC-2CI4UWE.2
3" UMDC-3CI4UWE.2
4" UMDC-4CI4UWE.2
6" UMDC-6CI4UWE.2
Universal actuator
Choose interface:
Standard none EUD-CI4UWE.2
2" EUD-2CI4UWE.2
3" EUD-3CI4UWE.2
4" EUD-4CI4UWE.2
6" EUD-6CI4UWE.2
RS-232 none EUDA-CI4UWE.2
2" EUDA-2CI4UWE.2
3" EUDA-3CI4UWE.2
4" EUDA-4CI4UWE.2
6" EUDA-6CI4UWE.2
RS-485 none EUDF-CI4UWE.2
2" EUDF-2CI4UWE.2
3" EUDF-3CI4UWE.2
4" EUDF-4CI4UWE.2
6" EUDF-6CI4UWE.2
USB none EUDB-CI4UWE.2
2" EUDB-2CI4UWE.2
3" EUDB-3CI4UWE.2
4" EUDB-4CI4UWE.2
6" EUDB-6CI4UWE.2
BCD none EUDC-CI4UWE.2
2" EUDC-2CI4UWE.2
3" EUDC-3CI4UWE.2
4" EUDC-4CI4UWE.2
6" EUDC-6CI4UWE.2
Replacement parts Product No.
Valve (for use with existing actuator) DCI4UWE.2
Rotor SSACI4UWE.2
Med temp
Internal sample
1/16" 0.75 mm
4 port schematic

.5 µl injectors

Microelectric and universal actuators:
   24 VDC, with 110/230 VAC to 24 VDC power supply

Actuation Standoff Product No.
Manual none CI4UWE.5
2" 2CI4UWE.5
3" 3CI4UWE.5
4" 4CI4UWE.5
6" 6CI4UWE.5
With air actuator none ACI4UWE.5
2" A2CI4UWE.5
3" A3CI4UWE.5
4" A4CI4UWE.5
6" A6CI4UWE.5
With Modular Universal Actuator
Choose interface:
Standard none UMD-CI4UWE.5
2" UMD-2CI4UWE.5
3" UMD-3CI4UWE.5
4" UMD-4CI4UWE.5
6" UMD-6CI4UWE.5
RS-232 none UMDA-CI4UWE.5
2" UMDA-2CI4UWE.5
3" UMDA-3CI4UWE.5
4" UMDA-4CI4UWE.5
6" UMDA-6CI4UWE.5
RS-485 none UMDF-CI4UWE.5
2" UMDF-2CI4UWE.5
3" UMDF-3CI4UWE.5
4" UMDF-4CI4UWE.5
6" UMDF-6CI4UWE.5
BCD none UMDC-CI4UWE.5
2" UMDC-2CI4UWE.5
3" UMDC-3CI4UWE.5
4" UMDC-4CI4UWE.5
6" UMDC-6CI4UWE.5
Universal actuator
Choose interface:
Standard none EUD-CI4UWE.5
2" EUD-2CI4UWE.5
3" EUD-3CI4UWE.5
4" EUD-4CI4UWE.5
6" EUD-6CI4UWE.5
RS-232 none EUDA-CI4UWE.5
2" EUDA-2CI4UWE.5
3" EUDA-3CI4UWE.5
4" EUDA-4CI4UWE.5
6" EUDA-6CI4UWE.5
RS-485 none EUDF-CI4UWE.5
2" EUDF-2CI4UWE.5
3" EUDF-3CI4UWE.5
4" EUDF-4CI4UWE.5
6" EUDF-6CI4UWE.5
USB none EUDB-CI4UWE.5
2" EUDB-2CI4UWE.5
3" EUDB-3CI4UWE.5
4" EUDB-4CI4UWE.5
6" EUDB-6CI4UWE.5
BCD none EUDC-CI4UWE.5
2" EUDC-2CI4UWE.5
3" EUDC-3CI4UWE.5
4" EUDC-4CI4UWE.5
6" EUDC-6CI4UWE.5
Replacement parts Product No.
Valve (for use with existing actuator) DCI4UWE.5
Rotor SSACI4UWE.5
Med temp
Internal sample
1/16" 0.75 mm
4 port schematic

1 µl injectors

Microelectric and universal actuators:
   24 VDC, with 110/230 VAC to 24 VDC power supply

Actuation Standoff Product No.
Manual none CI4UWE1
2" 2CI4UWE1
3" 3CI4UWE1
4" 4CI4UWE1
6" 6CI4UWE1
With air actuator none ACI4UWE1
2" A2CI4UWE1
3" A3CI4UWE1
4" A4CI4UWE1
6" A6CI4UWE1
With Modular Universal Actuator
Choose interface:
Standard none UMD-CI4UWE1
2" UMD-2CI4UWE1
3" UMD-3CI4UWE1
4" UMD-4CI4UWE1
6" UMD-6CI4UWE1
RS-232 none UMDA-CI4UWE1
2" UMDA-2CI4UWE1
3" UMDA-3CI4UWE1
4" UMDA-4CI4UWE1
6" UMDA-6CI4UWE1
RS-485 none UMDF-CI4UWE1
2" UMDF-2CI4UWE1
3" UMDF-3CI4UWE1
4" UMDF-4CI4UWE1
6" UMDF-6CI4UWE1
BCD none UMDC-CI4UWE1
2" UMDC-2CI4UWE1
3" UMDC-3CI4UWE1
4" UMDC-4CI4UWE1
6" UMDC-6CI4UWE1
Universal actuator
Choose interface:
Standard none EUD-CI4UWE1
2" EUD-2CI4UWE1
3" EUD-3CI4UWE1
4" EUD-4CI4UWE1
6" EUD-6CI4UWE1
RS-232 none EUDA-CI4UWE1
2" EUDA-2CI4UWE1
3" EUDA-3CI4UWE1
4" EUDA-4CI4UWE1
6" EUDA-6CI4UWE1
RS-485 none EUDF-CI4UWE1
2" EUDF-2CI4UWE1
3" EUDF-3CI4UWE1
4" EUDF-4CI4UWE1
6" EUDF-6CI4UWE1
USB none EUDB-CI4UWE1
2" EUDB-2CI4UWE1
3" EUDB-3CI4UWE1
4" EUDB-4CI4UWE1
6" EUDB-6CI4UWE1
BCD none EUDC-CI4UWE1
2" EUDC-2CI4UWE1
3" EUDC-3CI4UWE1
4" EUDC-4CI4UWE1
6" EUDC-6CI4UWE1
Replacement parts Product No.
Valve (for use with existing actuator) DCI4UWE1
Rotor SSACI4UWE1
Med temp
Internal sample
1/16" 0.75 mm
4 port schematic

2 µl injectors

Microelectric and universal actuators:
   24 VDC, with 110/230 VAC to 24 VDC power supply

Actuation Standoff Product No.
Manual none CI4UWE2
2" 2CI4UWE2
3" 3CI4UWE2
4" 4CI4UWE2
6" 6CI4UWE2
With air actuator none ACI4UWE2
2" A2CI4UWE2
3" A3CI4UWE2
4" A4CI4UWE2
6" A6CI4UWE2
With Modular Universal Actuator
Choose interface:
Standard none UMD-CI4UWE2
2" UMD-2CI4UWE2
3" UMD-3CI4UWE2
4" UMD-4CI4UWE2
6" UMD-6CI4UWE2
RS-232 none UMDA-CI4UWE2
2" UMDA-2CI4UWE2
3" UMDA-3CI4UWE2
4" UMDA-4CI4UWE2
6" UMDA-6CI4UWE2
RS-485 none UMDF-CI4UWE2
2" UMDF-2CI4UWE2
3" UMDF-3CI4UWE2
4" UMDF-4CI4UWE2
6" UMDF-6CI4UWE2
BCD none UMDC-CI4UWE2
2" UMDC-2CI4UWE2
3" UMDC-3CI4UWE2
4" UMDC-4CI4UWE2
6" UMDC-6CI4UWE2
Universal actuator
Choose interface:
Standard none EUD-CI4UWE2
2" EUD-2CI4UWE2
3" EUD-3CI4UWE2
4" EUD-4CI4UWE2
6" EUD-6CI4UWE2
RS-232 none EUDA-CI4UWE2
2" EUDA-2CI4UWE2
3" EUDA-3CI4UWE2
4" EUDA-4CI4UWE2
6" EUDA-6CI4UWE2
RS-485 none EUDF-CI4UWE2
2" EUDF-2CI4UWE2
3" EUDF-3CI4UWE2
4" EUDF-4CI4UWE2
6" EUDF-6CI4UWE2
USB none EUDB-CI4UWE2
2" EUDB-2CI4UWE2
3" EUDB-3CI4UWE2
4" EUDB-4CI4UWE2
6" EUDB-6CI4UWE2
BCD none EUDC-CI4UWE2
2" EUDC-2CI4UWE2
3" EUDC-3CI4UWE2
4" EUDC-4CI4UWE2
6" EUDC-6CI4UWE2
Replacement parts Product No.
Valve (for use with existing actuator) DCI4UWE2
Rotor SSACI4UWE2

SPECIFICATIONS

Max pressure: 1000 psi
Max temp: 175°C
Body: Nitronic 60
Rotor: Valcon E

OPTIONS

Contact us for more info about:

MORE INFORMATION

STANDOFFS

GC valves usually require a standoff - an extension between the valve and actuator which allows the valve to be mounted in the heated zone while the actuator or handle remains outside at ambient temperature.